Skip to content
LEVERMOUNT – Weigh module

LEVERMOUNT – Weigh module

Pavone Sistemi LEVERMOUNT is a robust and precise weigh module with an integrated stainless steel load cell, designed for industrial weighing of tanks and vessels. The module has a stable construction with three fixing points and can be adapted for both radial and tangential mounting.

LEVERMOUNT is designed to allow natural expansion and contraction in the tank structure without affecting the installation. The system also makes it possible to lift the tank without using a jack, which makes installation and maintenance easier.

LEVERMOUNT is available with weighing capacities from 300 to 5,000 kg and features IP68 protection and OIML accuracy class 3000. The weigh module has a combined error of less than ±0.017% and a safe overload of 150% of the rated capacity. In addition, LEVERMOUNT is ATEX-certified and well suited to industrial weighing installations where precision, stability and operational reliability are essential.

Product brochures

Do you need help?

If you would like to hear more about our solutions, please fill out the form and we will contact you as soon as possible.

If you need urgent assistance, you can contact us 24/7/365 on +45 75 60 22 22.

Call +45 75 60 22 22

*
Read our privacy policy

Model

SelectModelRated load (RL)
LEVERMOUNT300, 500, 1,000, 1,500, 2,000, 2,500, 3,000 and 5,000 kg

Select the products you're interested in and send us an enquiry using the form below.

Technical details – Pavone Sistemi LEVERMOUNT

Abbreviations: RL = rated load. RO = rated output.

Specification Value
Rated load (RL) 300, 500, 1,000, 1,500, 2,000, 2,500, 3,000 and 5,000 kg
Combined error
Repeatability
Creep (30 minutes) ±0.016% RO
Safe overload 150% RL
Ultimate overload 200% RL
Tightening torque without load RL 300–2,000 kg: 136 Nm; RL 3,000–5,000 kg: 205 Nm
Protection class IP68
Accuracy class OIML 3000
Deflection under load 0.2–0.4 mm
Compensated temperature range -10 to +40 °C
Operating temperature range -30 to +70 °C
Temperature effect on zero ±0.002% RO/°C
Temperature effect on output
Rated output (RO) 2 mV/V ±0.05%
Zero balance ±2% RO
Insulation resistance > 5,000 MΩ at 100 V DC
Input resistance 400 ±20 Ω
Output resistance 350 ±3 Ω
Recommended supply voltage 5–15 V DC/AC

Didn’t find what you were looking for?

We have a wider range of load cell mounting kits than you will find on our website. Contact us and we will help you find exactly the right mounting kit for your load cells.

Contact us for more info