Skip to content
65023 – Shear Beam Load Cell

65023 – Shear Beam Load Cell

Pavone Sistemi 65023 is a robust and precise shear beam load cell in nickel-plated steel or stainless steel, developed for industrial weighing of tanks, vessels and weighing platforms with a low installation height.

The load cell has IP67 protection, high measuring accuracy and withstands side loads of up to 100% of the rated capacity. It is available with weighing capacities from 125 kg to 5,000 kg and has a combined error of ±0.02% and a repeatability of ±0.01% of the rated output.

The 65023 is also available in a special high-temperature version and can be supplied with MKX or MH mounting kits for easier installation. Selected capacities have OIML accuracy class 3000.

Product brochures

Do you need help?

If you would like to hear more about our solutions, please fill out the form and we will contact you as soon as possible.

If you need urgent assistance, you can contact us 24/7/365 on +45 75 60 22 22.

Call +45 75 60 22 22

*
Read our privacy policy

Model

SelectModelRated load (RL)
65023125, 250, 500, 750, 1000, 1500, 2000, 3000, 5000 Kg

Select the products you're interested in and send us an enquiry using the form below.

Technical details – Pavone Sistemi 65023

Abbreviations: RL = rated load. RO = rated output.

Specification Value
Rated load (RL) 125, 250, 500, 750, 1,000, 1,500, 2,000, 3,000 and 5,000 kg
Combined error ±0.02% RO
Repeatability ±0.01% RO
Creep (20 minutes) ±0.017% RO
Safe overload 150% RL
Ultimate overload 300% RL
Tightening torque without load 125–2,000 kg: 136 Nm; 3,000–5,000 kg: 205 Nm
Material Nickel-plated steel or stainless steel
Protection class IP67
Accuracy class OIML 3000 (500–5,000 kg)
Deflection under load 0.33–0.89 mm
Compensated temperature range -10 to +40 °C
Operating temperature range -18 to +65 °C
Temperature effect on zero ±0.018% RO / 10 °C
Temperature effect on output ±0.012% of output / 10 °C
Rated output (RO) 3 mV/V ±0.25%
Zero balance ±1% RO
Insulation resistance > 1,000 MΩ
Input resistance 343–357 Ω
Output resistance 349–355 Ω
Recommended excitation voltage 5–15 V DC/AC

Didn’t find what you were looking for?

We have a wider range of load cells than you will find on our website. Contact us and we will help you find exactly the right load cell for your production.

Contact us for more information